VR Series Stainless Picket Railing

Stainless picket railing with 4-inch spacing that guides employees and keeps carts, tools and product from passing through.

VR Series stainless steel employee guidance railing for food processing and pharmaceutical manufacturing facilities

Designed for food processing and pharmaceutical manufacturing facilities, our stainless steel employee guidance railings direct workers safely through walkways, processing lines, and hygiene zones. By controlling traffic patterns, they maintain sanitary flow and reduce the risk of cross-contamination between clean and dirty areas.

Key Features of the VR Series Safety Railing

  • OSHA-Compliant: Designed to meet OSHA 29 CFR 1910.29 guardrail requirements.
  • Hygienic Design: Smooth finish and continuous welds prevent buildup, making cleaning easy. 
  • Modular & Adaptable: Easily installed or expanded.

Technical Specifications

  • Height (in): 42
  • Available Lengths (in): 12 to 72 inches in 12-inch increments
  • Pickets on 4-inch centers
  • Custom size on request
  • Tube Specs: 304 Stainless Steel, 1.5-inch dia x 0.120-inch wall
  • Surface Finish: #4
  • Mounting Options: 4 x 4 plate, triangular plate, or 6-inch extensions to embed in concrete
ItemTypeMaterialFinishLength (inches)Height (inches).pdf.dwg.stepImage
VR 48-42Vertical Rail304 Stainless Steel#44842.pdfpng
VR 60-42Vertical Rail304 Stainless Steel#46042.pdfpng
VR 72-42Vertical Rail304 Stainless Steel#47242.pdfpng
VR 36-42Vertical Rail304 Stainless Steel#43642.pdfpng
VR 24-42Vertical Rail304 Stainless Steel#42442.pdfpng
VR 12-42Vertical Rail304 Stainless Steel#41242.pdfpng

Safety Railing Compliance Checklist

 

1. General OSHA Compliance

  • Railings placed in aisles/passageways to protect employees (OSHA 1910.176)
  • If used as fall protection → meets 1910.28 & 1910.29 requirements:
    • Top rail height: 42 in ± 3 in
    • Mid-rail halfway between top rail and floor
    • Must withstand 200 lb force outward/downward
  • Barriers protect from contact with machines/vehicles if applicable (1910.212)
  • Installation does not create tripping hazards (General Duty Clause)

2. ANSI Best Practices

  • Complies with ANSI A1264.1 (Safety for Walking/Working Surfaces)
  • Railings clearly separate pedestrian and equipment traffic
  • Minimum 36 in clearance for walkways (OSHA & ANSI guidance)
  • Smooth, continuous railing with no sharp edges

3. Food & Pharmaceutical Standards

  • Constructed from 304 stainless steel (corrosion-resistant)
  • Surfaces are smooth, polished (No. 4 finish or better) for cleanability
  • Welds are ground and polished; no crevices that trap debris or bacteria
  • Compatible with CIP (Clean-in-Place) or manual washdown processes
  • Meets FDA cGMP requirements for sanitary design
  • Aligns with 3-A Sanitary Standards or EHEDG guidelines (Europe)

4. Installation & Safety

  • Securely anchored to floor with hygienic bases (no exposed threads)
  • Proper spacing: railings guide traffic without blocking emergency egress
  • End caps sealed to prevent water ingress
  • Adequate lighting and marking for visibility in walkways

5. Documentation

  • Material certifications (stainless steel grade, surface finish)
  • Cleaning and maintenance procedures documented
  • Installation drawings and OSHA/ANSI compliance statement provided

This checklist is general guidance and the customer should confirm compliance for their site.

Download Checklist